BwUniCluster 2.0 Maintenance/2020-10/Software Issues

From bwHPC Wiki
< BwUniCluster 2.0 Maintenance‎ | 2020-10
Revision as of 11:00, 27 October 2020 by S Raffeiner (talk | contribs) (Created page with "After the last maintenance the default settings of the following software modules offered on the system are currently know to be be in...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

After the last maintenance the default settings of the following software modules offered on the system are currently know to be be incompatible with the new system:

  • ANSYS Mechanical and Fluent: The software has to be switched to OpenMPI using the -mpi=openmpi command line argument.
  • ANSYS CFX: The software has to be switched to OpenMPI using the -start-method 'Open MPI Distributed Parallel' command line argument.
  • For the cae/abaqus/2019 module there is currently no known fix. We are working on a solution.